Refrigerant Pressure Sensor / Switch: Service and Repair
CONDENSER
REFRIGERANT PRESSURE SENSOR : Removal and Installation
REMOVAL
1.Remove liquid tank. Service and Repair.
2.Fix the liquid tank (1) with a vise (A). Remove the refrigerant pressure sensor (2) with a wrench (B).
CAUTION:
- Be careful not to damage liquid tank.
- To prevent the inclusion of foreign matter, cap or wrap the joint of the refrigerant pressure sensor and liquid tank with suitable material such as vinyl tape to avoid the entry of air.
INSTALLATION
Note the following items, and install in the reverse order of removal.
CAUTION:
To prevent leakage of refrigerant, replace the O-ring with a new one. Apply a coat of compressor oil to the O-ring prior to installation.