5AT RE5R05A
P0615 STARTER RELAY
Description
TCM prohibits cranking other than at "P" or "N" position.
CONSULT-III Reference Value in Data Monitor Mode
On Board Diagnosis Logic
- This is not an OBD-II self-diagnostic item.
- Diagnostic trouble code "P0615" with CONSULT-III or 14th judgment flicker without CONSULT-III is detected when starter relay is switched ON other than at "P" or "N" position. (Or when switched OFF at "P" or "N" position).
Possible Cause
- Harness or connectors
(Starter relay and TCM circuit is open or shorted.)
- Starter relay circuit
DTC Confirmation Procedure
NOTE:
If "DTC Confirmation Procedure" has been previously performed, always turn ignition switch OFF and wait at least 10 seconds before performing the next test.
After the repair, perform the following procedure to confirm the malfunction is eliminated.
WITH CONSULT-III
1. Shift the selector lever to "P" or "N" position.
2. Turn ignition switch ON and wait for at least 2 consecutive seconds.
3. Select "SELF-DIAG RESULTS" in "TRANSMISSION".
4. If DTC is detected, go to 5AT RE5R05A.
Wiring Diagram - AT - STSIG
Diagnosis Procedure
1.CHECK STARTER RELAY
With CONSULT-III
1. Turn ignition switch ON.
2. Select "SELECTION FROM MENU" in "DATA MONITOR" in "TRANSMISSION" and check monitor "STARTER RELAY" ON/OFF. Refer to 5AT RE5R05A.
Without CONSULT-III
1. Turn ignition switch ON.
2. Check voltage between the IPDM E/R connector and ground.
OK or NG
OK - GO TO 5.
NG - GO TO 2.
2. CHECK HARNESS BETWEEN A/T ASSEMBLY HARNESS CONNECTOR AND IPDM E/R CONNECTOR
1. Turn ignition switch OFF.
2. Disconnect A/T assembly harness connector and IPDM E/R connector.
3. Check continuity between A/T assembly harness connector and
IPDM E/R connector.
4. If OK, check harness for short to ground and short to power.
5. Reinstall any part removed.
OK or NG
OK - GO TO 3.
NG - Repair open circuit or short to ground or short to power in harness or connectors.
3.CHECK TERMINAL CORD ASSEMBLY
1. Remove control valve with TCM. Refer to Service and Repair.
2. Disconnect A/T assembly harness connector and TCM connector.
3. Check continuity between A/T assembly harness connector terminal and TCM connector terminal.
4. If OK, check harness for short to ground and short to power.
5. Reinstall any part removed.
OK or NG
OK - GO TO 4.
NG - Replace open circuit or short to ground and short to power in harness or connectors.
4.DETECT MALFUNCTIONING ITEM
Check the following.
- Starter relay, Refer to Description and Operation.
- IPDM E/R, Refer to System Description.
OK or NG
OK - Replace the control valve with TCM. Refer to Service and Repair.
NG - Repair or replace damaged parts.
5.CHECK DTC
Perform 5AT RE5R05A.
OK or NG
OK INSPECTION END
NG - GO TO 2.