Internal Fault. Permanent Fault






Internal fault. Permanent fault

Checking the wiring




- Ignition off.
Check the ultrasonic sensor control module connectors for contact resistance and oxidation according to Checking wiring and terminals. Permanent fault Checking Wiring And Terminals. Permanent Fault.
Check the cable between the ultrasonic sensor control module #B1 and the sender microphone #1 for a short-circuit to ground according to Checking wiring and terminals. Permanent fault Checking Wiring And Terminals. Permanent Fault , short-circuit to supply voltage according to Checking wiring and terminals. Permanent fault Checking Wiring And Terminals. Permanent Fault and for an open-circuit according to Checking wiring and terminals. Permanent fault Checking Wiring And Terminals. Permanent Fault.
Check the cable between the ultrasonic sensor control module #B2 and the sender microphone #2 for a short-circuit to ground according to Checking wiring and terminals. Permanent fault Checking Wiring And Terminals. Permanent Fault , short-circuit to supply voltage according to Checking wiring and terminals. Permanent fault Checking Wiring And Terminals. Permanent Fault and for an open-circuit according to Checking wiring and terminals. Permanent fault Checking Wiring And Terminals. Permanent Fault.
Check the cable between the ultrasonic sensor control module #B4 and the receiver microphone #1 for a short-circuit to ground according to Checking wiring and terminals. Permanent fault Checking Wiring And Terminals. Permanent Fault , short-circuit to supply voltage according to Checking wiring and terminals. Permanent fault Checking Wiring And Terminals. Permanent Fault and for an open-circuit according to Checking wiring and terminals. Permanent fault Checking Wiring And Terminals. Permanent Fault.
Check the cable between the ultrasonic sensor control module #B5 and the receiver microphone #2 for a short-circuit to ground according to Checking wiring and terminals. Permanent fault Checking Wiring And Terminals. Permanent Fault , short-circuit to supply voltage according to Checking wiring and terminals. Permanent fault Checking Wiring And Terminals. Permanent Fault and for an open-circuit according to Checking wiring and terminals. Permanent fault Checking Wiring And Terminals. Permanent Fault.

Other information:
- To access / replace the ultrasonic sensor control module, see Ultrasonic or glass breakage control module Ultrasonic Or Glass Breakage Control Module.
- To access / replace the ultrasonic sensor microphones, see Ultransonic sensor and cable harness Removal and Replacement.
Remedy as necessary.









Was a fault detected?

Yes - Verification

No - Replacing the component

-------------------------------------------------

Replacing the component
Try new ultrasonic sensor microphones.

Other information:
- To access / replace the ultrasonic sensor microphones, see Ultransonic sensor and cable harness Removal and Replacement.





Select "Continue" when complete.

Continue - Verification

-------------------------------------------------

Verification

Hint: After carrying out the repair, check that the fault has been remedied as follows:




- Remove the key from the ignition switch.
- Ensure that all doors and hatches are shut including the hood and the trunk lid / tailgate.
- Activate the alarm by locking the car using the remote control. Wait approximately 30 seconds. Unlock the car again.
- Ignition on.
Read off diagnostic trouble code (DTC) status.
The status of the relevant diagnostic trouble code (DTC) should be intermittent.





Does the status display an intermittent fault?

Yes - FAULT FOUND

No - Fault-tracing information

-------------------------------------------------

Fault-tracing information




Information

Fault-tracing information
The fault should have been detected and remedied. As this is not the case fault-tracing has failed.
Exit fault-tracing for this diagnostic trouble code (DTC) or make another attempt.

Do you want to exit fault-tracing?

Yes - FAULT-TRACING FAILED

No - Attempt New Test

------------------------

FAULT-TRACING FAILED - No Fault Found

Attempt New Test - Checking the wiring

-------------------------------------------------