Internal Fault. Intermittent Fault
Internal fault. Intermittent fault
Checking wiring and connectors
Check the ultrasonic sensor control module connectors for contact resistance and oxidation according to Checking wiring and terminals. Intermittent faults Checking Wiring And Terminals. Intermittent Faults and loose connections according to Checking wiring and terminals. Intermittent faults Checking Wiring And Terminals. Intermittent Faults.
Check the cable between ultrasonic sensor control module #B1 and sender microphone #1 for an intermittent open-circuit according to Checking wiring and terminals. Intermittent faults Checking Wiring And Terminals. Intermittent Faults , an intermittent short-circuit to ground according to Checking wiring and terminals. Intermittent faults Checking Wiring And Terminals. Intermittent Faults and an intermittent short-circuit to supply voltage according to Checking wiring and terminals. Intermittent faults Checking Wiring And Terminals. Intermittent Faults.
Check the cable between ultrasonic sensor control module #B2 and sender microphone #2 for an intermittent open-circuit according to Checking wiring and terminals. Intermittent faults Checking Wiring And Terminals. Intermittent Faults , an intermittent short-circuit to ground according to Checking wiring and terminals. Intermittent faults Checking Wiring And Terminals. Intermittent Faults and an intermittent short-circuit to supply voltage according to Checking wiring and terminals. Intermittent faults Checking Wiring And Terminals. Intermittent Faults.
Check the cable between ultrasonic sensor control module #B4 and receiver microphone #1 for an intermittent open-circuit according to Checking wiring and terminals. Intermittent faults Checking Wiring And Terminals. Intermittent Faults , an intermittent short-circuit to ground according to Checking wiring and terminals. Intermittent faults Checking Wiring And Terminals. Intermittent Faults and an intermittent short-circuit to supply voltage according to Checking wiring and terminals. Intermittent faults Checking Wiring And Terminals. Intermittent Faults.
Check the cable between ultrasonic sensor control module #B5 and receiver microphone #2 for an intermittent open-circuit according to Checking wiring and terminals. Intermittent faults Checking Wiring And Terminals. Intermittent Faults , an intermittent short-circuit to ground according to Checking wiring and terminals. Intermittent faults Checking Wiring And Terminals. Intermittent Faults and an intermittent short-circuit to supply voltage according to Checking wiring and terminals. Intermittent faults Checking Wiring And Terminals. Intermittent Faults.
Check that the cable is not near a source of interference.
Other information:
- To access / replace the ultrasonic sensor control module, see Ultrasonic or glass breakage control module Ultrasonic Or Glass Breakage Control Module.
- To access / replace the ultrasonic sensor microphones, see Ultransonic sensor and cable harness Removal and Replacement.
- For information about signals, see Signal specification, lock and alarm, (VGLA) Signal Specification.
Select Continue.
Continue - Fault-tracing information
No Fault Found
-------------------------------------------------
Fault-tracing information
Information
Fault-tracing information
If the fault is intermittent, do not verify fault-tracing if the fault does not recur.
It is possible to view the information again, or leave fault-tracing for this diagnostic trouble code (DTC).
Do you want to view the information again?
Yes - Attempt New Test
No - FAULT FOUND
------------------------
FAULT FOUND - FAULT FOUND
Attempt New Test - Checking wiring and connectors
-------------------------------------------------