Operation CHARM: Car repair manuals for everyone.
Hosted by mcallihan.com

Open-Circuit






Open-circuit

Checking lock-up solenoid SL




- Ignition on.
- Move gear selector to position P.
Activate solenoid SL. Read off the solenoid status. The status should alternate between OFF/ON.





Does the status alternate?

Yes - Intermittent fault

No - Checking ground terminal
Checking power ground

-------------------------------------------------

Checking power ground





Connecting the breakout box
951 1355 Adapter 42-pin 951 1355 Adapter 42-pin 981 3190 Replaced by 9511428 981 3190 Replaced by 951 1428




Information

Connecting the breakout box to AW50-42





Is the breakout box connected to the control module?

Yes - CONNECTEDReturn to fault-tracing.

No - NOT CONNECTED

------------------------

CONNECTED - CONNECTED

NOT CONNECTED - Connecting the breakout box

-------------------------------------------------

Connecting the breakout box




Connecting the breakout box
981 3190 Replaced by 9511428 981 3190 Replaced by 951 1428 951 1355 Adapter 42-pin 951 1355 Adapter 42-pin
Connecting the breakout box

Caution! The voltage supply to the control module must be disconnected when disconnecting the breakout box. Failure to observe this procedure could seriously damage the control module.








- Ignition off
- Expose and disconnect the AW50-42 transmission control module (TCM) according to Replacing the transmission control module (TCM) .
- Control module disconnected.
Connect adapter 951 1355 Adapter 42-pin 951 1355 Adapter 42-pin to the control module connector (wiring side). Connect breakout box 981 3190 Replaced by 9511428 981 3190 Replaced by 951 1428 to the adapter.

Note! Ensure that the adapter is the right way around.









Continue - DONE

------------------------

DONE - Checking the ground terminal

-------------------------------------------------

Checking the ground terminal








- Ignition off.
- Control module disconnected.
- Switch off all power consuming equipment, such as courtesy lighting, radio etc.
Connect an ohmmeter between terminal 1 on the breakout box and the battery negative terminal.









The ohmmeter should read approximately 0 ohms.

OK - Return to the fault-tracing procedure where it was interrupted.
No Fault Found

Not OK - Checking for an open-circuit, contact resistance and oxidation

-------------------------------------------------

Checking for an open-circuit, contact resistance and oxidation
Check ground terminal 31/20 and the lead between the ground terminal and control module #1 for open-circuit according to Checking wiring and terminals. Permanent fault Checking Wiring And Terminals. Permanent Fault and contact resistance and oxidation according to Checking wiring and terminals. Permanent fault Checking Wiring And Terminals. Permanent Fault.
Check the ground lead between the battery and the body for an open-circuit according to Checking wiring and terminals. Permanent fault Checking Wiring And Terminals. Permanent Fault and contact resistance and oxidation according to Checking wiring and terminals. Permanent fault Checking Wiring And Terminals. Permanent Fault.





Continue - Verification

-------------------------------------------------

Verification




Verification

Hint: After repairs have been completed they must be verified as follows to ensure that the fault has been eliminated:








- Ignition off
- Switch off all power consuming equipment, such as courtesy lighting, radio etc.
- Control module disconnected
Connect an ohmmeter between #1 on the breakout box and the battery negative terminal.









The ohmmeter should read approximately 0 ohms.

OK - VERIFIED

Not OK - VERIFICATION FAILED

------------------------

VERIFIED - FAULT FOUND

VERIFICATION FAILED - Fault-tracing information

-------------------------------------------------

Fault-tracing information




Information

Fault-tracing information
The fault should be diagnosed and remedied. Since this is not the case the fault-tracing process has failed.
Complete the fault-tracing for those fault or try again.

Do you want to terminate fault-tracing at this time?

Yes - Exit fault-tracing

No - Attempt New Test

------------------------

Attempt New Test - Connecting the breakout box

-------------------------------------------------

CONNECTED - Checking resistance in solenoid SL circuit

No Fault Found - Checking resistance in solenoid SL circuit

FAULT-TRACING FAILED - Checking resistance in solenoid SL circuit

FAULT FOUND - Fault-tracing information

-------------------------------------------------

Fault-tracing information
The cause of the diagnostic trouble code (DTC) has been a poor ground terminal.

Continue - Verification

-------------------------------------------------

Checking resistance in solenoid SL circuit








- Ignition off.
- Control module disconnected.
Connect an ohmmeter between #2 and #1 on the breakout box.









The ohmmeter should read approximately 12-16 ohms.

OK - Checking transmission control module (TCM)

Not OK - Checking the signal cable

-------------------------------------------------

Checking transmission control module (TCM)




- Ignition on.
- Move gear selector to position P.
Read off solenoid SL status. Its status should alternate between OFF/ON.





Does the status alternate?

Yes - Checking for contact resistance and oxidation

No - Replacing component

-------------------------------------------------

Checking for contact resistance and oxidation
The cause of the diagnostic trouble code (DTC) has been loose connections in the control module connector. Check connector for contact resistance and oxidation and remedy according to Checking wiring and terminals. Permanent fault Checking Wiring And Terminals. Permanent Fault.

Continue - Verification

-------------------------------------------------

Replacing component
Try a new control module according to Replacing the transmission control module (TCM) .





Continue - Verification

-------------------------------------------------

Checking the signal cable








- Ignition off.
- Disconnect 6-pin transmission connector. For further information about connectors, see Transmission connectors Transmission Connectors.
Connect an ohmmeter between transmission connector terminal 2 (transmission control module (TCM) side) and #2 on the breakout box.









The ohmmeter should read approximately 0 ohms.

OK - Checking solenoid SL circuit in the transmission

Not OK - Checking for an open-circuit

-------------------------------------------------

Checking for an open-circuit
Check cable between transmission connector terminal 2 and transmission control module (TCM) #2 for an open-circuit according to Checking wiring and terminals. Permanent fault Checking Wiring And Terminals. Permanent Fault.









Continue - Verification

-------------------------------------------------

Checking solenoid SL circuit in the transmission








- Ignition off.
- Disconnect 6-pin transmission connector.
Connect an ohmmeter between the 6-pin transmission connector terminal 2 (transmission side) and transmission housing.









The ohmmeter should read approximately 12-16 ohms.

OK - Checking for contact resistance and oxidation

Not OK - Checking resistance in solenoid SL

-------------------------------------------------

Checking for contact resistance and oxidation
The cause of the diagnostic trouble code (DTC) has been loose connections in the transmission connector. Check transmission and transmission control module (TCM) connectors for contact resistance and oxidation and remedy according to Checking wiring and terminals. Permanent fault Checking Wiring And Terminals. Permanent Fault.

Continue - Verification

-------------------------------------------------

Checking resistance in solenoid SL








- Ignition off.
- Open the control system according to Replacing control system Service and Repair.
- Disconnect solenoid SL.
Connect an ohmmeter between the pin on solenoid SL and the transmission housing (ground terminal).









The ohmmeter should read approximately 12-16 ohms.

OK - Checking for an open-circuit

Not OK - Replacing component

-------------------------------------------------

Checking for an open-circuit
Check the cable between solenoid SL and transmission connector terminal 2 for an open-circuit according to Checking wiring and terminals. Permanent fault Checking Wiring And Terminals. Permanent Fault.
Replacing the cable harness according to Inspecting / replacing the cable harness for the solenoids Inspecting / Replacing The Cable Harness For The Solenoids.









Continue - Verification

-------------------------------------------------

Replacing component
Try a new solenoid SL according to Solenoids, inspection/replacement Removal and Replacement.





Continue - Verification

-------------------------------------------------

Verification




Verification

Hint: After repairs have been completed they must be verified as follows to ensure that the fault has been eliminated:








- Ignition off.
- Reinstall the connectors, components etc.
- Ignition on.
- Gear selector in P.
Activate solenoid SL. Read off the status of the solenoid. The status should alternate between OFF / ON.





Does the status change?

Yes - VERIFIED

No - VERIFICATION FAILED

------------------------

VERIFIED - FAULT FOUND

VERIFICATION FAILED - Fault-tracing information

-------------------------------------------------

Fault-tracing information




Information

Fault-tracing information
The fault should have been detected and remedied. As this is not the case fault-tracing has failed.
Exit fault-tracing for this diagnostic trouble code (DTC) or make another attempt.

Do you want to exit fault-tracing?

Yes - Exit fault-tracing

No - Attempt New Test

------------------------

Attempt New Test - Checking lock-up solenoid SL

-------------------------------------------------

Intermittent fault





Open-circuit. Intermittent fault

Intermittent fault
- Check the 6-pin transmission connector and the control module connector for loose connections according to Checking wiring and terminals. Intermittent faults Checking Wiring And Terminals. Intermittent Faults. Check for contact resistance and oxidation according to Checking wiring and terminals. Intermittent faults Checking Wiring And Terminals. Intermittent Faults.
- Check the cable between solenoid SL in the transmission and control module terminal 2 for an intermittent open-circuit according to Checking wiring and terminals. Intermittent faults Checking Wiring And Terminals. Intermittent Faults.
- Check the cable between the ground terminal and control module terminal 2 for an intermittent open-circuit according to Checking wiring and terminals. Intermittent faults Checking Wiring And Terminals. Intermittent Faults.
- Check the ground terminal for contact resistance and oxidation according to Checking wiring and terminals. Intermittent faults Checking Wiring And Terminals. Intermittent Faults.





Continue - Fault-tracing information

------------------------

Fault-tracing information




Information

Fault-tracing information
If the fault is intermittent, do not verify fault-tracing if the fault does not recur.
It is possible to view the information again, or leave fault-tracing for this diagnostic trouble code (DTC).

Do you want to view the information again?

Yes - Attempt New Test

No - FAULT FOUND

-------------------------------------------------

Attempt New Test - Checking lock-up solenoid SL

-------------------------------------------------