Operation CHARM: Car repair manuals for everyone.
Hosted by mcallihan.com

Clearing Trouble Codes

CONSULT-II Functions

CONSULT-II FUNCTION APPLICATION TABLE








CAUTION:
^ Do not use the "function test" for diagnosis. For more information, refer to the separate volume "CONSULT-II OPERATION MANUAL (Function Test)".
^ When CONSULT-II is connected and communicating, ABS warning lamp, SLIP indicator lamp, and VDC OFF indicator lamp turn on, and when the communication is interrupted, the lamps will turn off after approximately 2 to 3 sec.
^ When the self-diagnosis, data monitor, or active test functions are being executed, ABS, TCS, and VDC control is not performed.
^ When using CONSULT-II to perform VDC/TCS/ABS control unit self-diagnosis, active test, work support, etc., first stop engine, connect CONSULT-II, and select "ABS".
^ When an error is shown by the CONSULT-II SELF-DIAG RESULTS and CONSULT-II is used to perform an active test, an engine system malfunction may be shown, but restarting engine will return the status to normal.
^ When data monitoring is executed by using CONSULT-II, a malfunction code may be indicated as the result of the real time diagnosis. In such a case, execute data monitoring in manual mode. Refer to CONSULT-II Operation Manual.

SELF-DIAGNOSIS
Description
If a malfunction is detected in system, ABS warning lamp, VDC OFF indicator lamp, and SLIP indicator lamp on meter turn on. In this case, perform self-diagnostic as follows:

Operation Procedure
1. Turn ignition switch OFF.





2. Connect CONSULT-II and CONSULT-II CONVERTER to data link connector (data link connector is on lower instrument cover).
3. Start engine and drive vehicle at approximately 30 km/h (19 MPH) for approximately 1 minute.
4. After stopping vehicle, with engine still idling, touch "START", "ABS", and "SELF-DIAG RESULTS" on CONSULT-II screen in this order.

CAUTION: Just after starting engine, or turning ignition switch ON, "ABS" may not be displayed on system selection screen even if "START" is touched. In this case, start self-diagnostic again from step 1. If it cannot be shown after several attempts, VDC/TCS/ABS control unit may have malfunctioned. Repair or replace control unit.

5. Self-diagnostic results is displayed. (If necessary, touch "PRINT" to print self-diagnostic results.)
^ When "NO FAILURE" is shown, check ABS warning lamp, VDC OFF indicator lamp, SLIP indicator lamp. Refer to "For Fast and Accurate Diagnosis". Precautions For Diagnosis
^ CONSULT-II self-diagnostic results are displayed without regard to occurrence timing. In some cases later ones (timing value is small) appear on next screen.
6. Go to appropriate "Inspection" chart according to "Display Item List", and repair or replace as necessary.
7. Start engine and drive vehicle at approximately 30 km/h (19 MPH) for approximately 1 minute.

CAUTION: Check again to make sure that there is no malfunction on other parts.

8. Turn ignition switch OFF to prepare for erasing memory.
9. Start engine and touch "START", "ABS", "SELF-DIAG RESULTS", and "ERASE MEMORY" on CONSULT-II screen in this order to erase memory.

CAUTION: If memory cannot be erased, go to step 6.

10. Drive vehicle at approximately 30 km/h (19 MPH) and make sure ABS warning lamp, VDC OFF indicator lamp, and SLIP indicator lamp stay off.

CAUTION: VDC "OFF" switch should not stay in the "ON" position.

Display Item List








Note 1. If wheel sensor 2 for each wheel is indicated, check control unit power supply voltage in addition to wheel sensor circuit check.
Note 2. If multiple malfunctions are detected including CAN communication line [U1000], perform diagnostic for CAN communication line first.

DATA MONITOR
^ For details of data monitor function, refer to "CONSULT-II operation Manual".

Operation Procedure
1. Turn ignition switch OFF.
2. Connect CONSULT-II and CONSULT-II CONVERTER to data link connector.
3. Turn ignition switch ON.
4. Touch "START" on display.
5. Touch "ABS" on display.

NOTE: Just after starting engine, or turning ignition switch ON, "ABS" may not be displayed on system selection screen even if "START" is touched. In this case, start again from step 1.

6. Touch "DATA MONITOR".
7. Return to monitor item selection screen, and touch any of "ECU INPUT SIGNALS", "MAIN SIGNALS", "SELECTION FROM MENU" or "CAN DIAGNOSIS SUPPORT MONITOR". Refer to "Display Item List".
8. Touch "START".
9. Screen of data monitor is displayed.














Display Item List

ACTIVE TEST
Operation Procedure

CAUTION:
^ Do not perform active test while driving vehicle.
^ Make sure to completely bleed air from brake system.
^ Active test cannot be performed when ABS, TCS or VDC operation is malfunction.

1. Connect CONSULT-II connector to vehicle-side data link connector and start engine.
2. Touch "START" on display.








3. Touch "ABS" and "ACTIVE TEST".





4. Test item selection screen is displayed.
5. Touch necessary test item.





6. Touch "START" with "MAIN SIGNALS" line inverted.





7. Active test screen is displayed.

Solenoid Valve





1. To perform active test of ABS functions, select major items for each test item. To perform active test of VDC/TCS functions, select item menu for each test item.
2. For ABS solenoid valve, touch "UP", "KEEP", and "DOWN". For ABS solenoid valve (ACT), touch "UP," "ACT UP," and "ACT KEEP". Use screen monitor to make sure solenoid valve operates as shown in Solenoid Valve Operation Chart. Refer to "Solenoid Valve Operation Chart".

Solenoid Valve Operation Chart








NOTE:
^ If active test is performed with brake pedal depressed, pedal stroke may change. This is normal.
^ "TEST STOP" is displayed approximately 10 seconds after operation starts.
^ After "TEST STOP" is displayed, touch "BACK" and perform the test from the step 6.

VDC Warning Lamp








Touch "ON" and "OFF" on screen. Make sure VDC OFF indicator lamp operates as shown in table below.

NOTE: If "OFF" is touched on screen during active test, VDC OFF indicator lamp, SLIP indicator lamp, and ABS warning lamp all turn ON for a moment. This is normal.

ABS Motor








Touch "ON" and "OFF" on screen. Make sure motor relay operates as shown in table below.

NOTE:
^ If active test is performed with brake pedal depressed, pedal stroke may change. This is normal.
^ "TEST STOP" is displayed approximately 10 seconds after operation starts.

SLIP Lamp








Touch "ON" and "OFF" on screen. Make sure SLIP indicator lamp operates as shown in table below.

NOTE: If "OFF" is touched on screen during active test, VI DC OFF indicator lamp, SLIP indicator lamp, and ABS warning lamp all turn ON for a moment. This is normal.

ABS Warning Lamp








Touch "ON" and "OFF" on screen. Make sure ABS warning lamp operates as shown in table below.

NOTE: If "OFF" is touched on screen during active test, VDC OFF indicator lamp, SLIP indicator lamp, and ABS warning lamp all turn ON for a moment. This is normal.