Operation CHARM: Car repair manuals for everyone.
Hosted by mcallihan.com

Intermittent Fault




Intermittent fault






Check outside temperature sensor and control module connectors for contact resistance and oxidation according to Checking wiring and terminals - Intermittent faults. Checking Wiring and Terminals

Check cable between ECC control module #A19 and outside temperature sensor terminal 2 for an intermittent open-circuit according to Checking wiring and terminals - Intermittent faults and an intermittent short-circuit to supply voltage according to Checking wiring and terminals - Intermittent faults. Checking Wiring and Terminals

Check cable between control module #A22 and outside temperature sensor terminal 4 for an open-circuit according to Checking wiring and terminals - Intermittent faults and an intermittent short-circuit to supply voltage according to Checking wiring and terminals - Intermittent faults. Checking Wiring and Terminals

Remedy as necessary.

Other information:

- To connect the breakout box Connection of Breakout Box ECC
- The voltage on the signal cable varies with temperature. At 20 °C (68 °F) voltage should be approximately 2.5 V. For other values, refer to Signal Specification ECC Signal Specification ECC