Operation CHARM: Car repair manuals for everyone.
Hosted by mcallihan.com

Checking Cables




Checking Cables







Check the control module and power unit connectors for contact resistance and oxidation according to Checking wiring and terminals - Permanent faults.

Check cable between control module #A14 and power unit for a short-circuit to ground according to Checking wiring and terminals - Permanent faults.

Check power supply to power unit #A4 for an open-circuit according to Checking wiring and terminals - Permanent faults.

Check ground lead between power unit #B2 and ground terminal for an open-circuit according to Checking wiring and terminals - Permanent faults. Checking Wiring and Terminals

Remedy as necessary.

Other information:
- To remove the control module, refer to Replacing ECC Control Module.
- To access the power unit, refer to Replacing power unit (ECC).

After performing this procedure Verification