H8 Checking Supply (15) to Fuse 11 In the Central Fuse Module
H8 Checking supply (15) to fuse 11 in the central fuse moduleSwitch ignition off.
Remove fuse 11.
Check fuse and replace if defective.
Switch ignition on.
Connect a voltmeter between ground and fusebox position 11C/11:2 for fuse 11. Voltmeter should read battery voltage.
If reading is correct:
Open-circuit in lead between fusebox position 11C/11:2 and relay base position 15.
Correct fault or replace lead.
Replace fuse 11.
Replace central locking relay D/G.
If reading is incorrect:
Open-circuit in supply lead to fusebox position 11C/11:2.
Correct fault or replace lead.
Replace fuse 11.
Replace central locking relay D/G.