TC. MFI #4 No Power Supply From Battery
TC. MFI#4
MFI#4 No power supply from battery
Fault message conditions:
The fault message is posted if voltage is below 1 V.
Fault causes:
Break in the wiring between MFI#4 and the battery.
Fault symptoms:
The OBD system is not working. The engine will not start if the fault exists.
TC1
Volvo ST, Test box
- Disconnect the ST in accordance with QA2. QA. Connecting The Volvo Scan Tool (ST)
- Connect the test box to MFI and check the GND points in accordance with P1-P2. P. Test Box, Signal Description
^ Continue with Checking the power supply TC2.
TC2
Checking the power supply
- Connect the control module to the test box.
- Install the fuse.
- Ignition on.
Connect a voltmeter between MFI#4 and MFI#5.
The voltmeter should read battery voltage.
If this value is OK
Intermittent fault.
^ Check the wiring between MFI#4 and the battery for loose contacts in accordance with NA5. NA. Checking the Wiring
If the reading Is incorrect
^ check the wiring between MFI#4 and the battery for breaks in accordance with NA2. NA. Checking the Wiring