B62-63: From B18: Control Pressure Too Low
From B18: Control pressure too low (warm control pressure regulator)When the fault has been rectified proceed with B19 B14-24: Checking All Pressures
B62
Check for voltage at the control pressure regulator
Measure across both the plug pins.
Voltage: measure the regulator resistance
10-20 ohm : regulator ...079 (USA 1981-)
20-30 ohm : others.
If the resistance is correct,the fault is due to a poor contact between the regulator and plug.
B63
Check for voltage between the plug and earth / ground
Voltage: open circuit in lead to earth.
No voltage: open circuit in lead between pump relay and control pressure regulator.