Wastegate Bypass Regulator Valve, Checking
Wastegate Bypass Regulator Valve, Checking
Special tools, testers and auxiliary items required
• Multimeter.
• Wiring diagram.
Test requirements
• The Diesel Direct Fuel Injection (DFI) Engine Control Module (ECM) (J248) fuses OK.
• Battery voltage at least 12.5 volts.
• All electrical consumers such as, lights and rear window defroster, switched off.
• On vehicles with automatic transmission, selector lever in position " P" or "N".
• A/C switched off.
• Ground (GND) connections between engine/transmission/chassis OK.
• Ignition switched off.
Test procedure
- Perform a preliminary check to verify the customers complaint. Refer to => [ Preliminary Check ] Preliminary Check.
Start diagnosis
- Disconnect the Wastegate Bypass Regulator Valve ( N75) electrical harness connector- 2 -.
Checking internal resistance
- Using a multimeter, check the Wastegate Bypass Regulator Valve (N75) - 1 - terminals 1 to 2 for resistance.
Specified value: 20 to 30 ohms (at approx. 20° C)
If the specification was not obtained:
- Replace the Wastegate Bypass Regulator Valve ( N75).
If the specification is obtained:
Checking Voltage supply
- Using a multimeter, check the Wastegate Bypass Regulator Valve (N75) electrical harness connector terminal 1 to Ground (GND).
- Operate the starter briefly.
Specified value: battery voltage.
- Switch the ignition off.
If the specification was not obtained:
- Check the wiring for a short circuit to Battery positive (+) or an open circuit.
- Check the electrical harness connector for damage, corrosion, loose or broken terminals.
- If necessary, repair the wiring connection.
If no malfunction is found in the wiring:
If the manufacturers test box is being used, perform the following step.
- Install the test box.
If the manufacturers test box is not being used, perform the following step.
- Remove the Diesel Direct Fuel Injection (DFI) Engine Control Module (ECM) (J248). Refer to => [ Engine Control Module, Replacing ] Engine Control Module, Replacing.
- Using a multimeter, check the Wastegate Bypass Regulator Valve (N75) electrical harness connector terminal 2 to the Diesel Direct Fuel Injection (DFI) Engine Control Module (ECM) (J248) electrical harness connector T60 terminal 29for an open circuit.
Specified value: 1.5 ohms max.
If the specification is not obtained:
- Check the wiring for a short circuit to each other, Battery (+), and Ground (GND).
- Check the electrical harness connector for damage, corrosion, loose or broken terminals.
- If necessary, repair the faulty wiring connection.
If no malfunction is detected in the wiring and if the voltage supply was OK:
- Replace the Diesel Direct Fuel Injection (DFI) Engine Control Module (ECM) (J248). Refer to => [ Engine Control Module, Replacing ] Engine Control Module, Replacing.
Final procedures
After the repair work, the following work steps must be performed in the following sequence:
1. Check the DTC memory. Refer to => [ Diagnostic Mode 03 - Read DTC Memory ] Diagnostic Mode 03 - Read DTC Memory.
2. If necessary, erase the DTC memory. Refer to => [ Diagnostic Mode 04 - Erase DTC Memory ] Diagnostic Mode 04 - Erase DTC Memory.
3. If the DTC memory was erased, generate readiness code. Refer to => [ Readiness Code ] Readiness Code.
End of diagnosis.