Hazard Warning Switch Circuit
LIGHTING (EXT): LIGHTING SYSTEM: Hazard Warning Switch Circuit
- Hazard Warning Switch Circuit
DESCRIPTION
The combination meter assembly receives the hazard switch ON signal and controls the operation of the hazard warning lights.
WIRING DIAGRAM
INSPECTION PROCEDURE
PROCEDURE
1. READ VALUE USING TECHSTREAM
(a) Connect the Techstream to the DLC3.
(b) Turn the power switch on (IG).
(c) Turn the Techstream on.
(d) Enter the following menus: Body Electrical / Combination Meter / Data List.
(e) Read the display on the Techstream.
Combination Meter
OK:
Normal conditions listed above are displayed.
NG -- INSPECT AIR CONDITIONING CONTROL ASSEMBLY (HAZARD SWITCH)
OK -- PROCEED TO NEXT SUSPECTED AREA SHOWN IN PROBLEM SYMPTOMS TABLE Problem Symptoms Table
2. INSPECT AIR CONDITIONING CONTROL ASSEMBLY (HAZARD SWITCH)
(a) Remove the air conditioning control assembly Removal.
(b) Measure the resistance according to the value(s) in the table below.
Standard Resistance:
Text in Illustration
NG -- REPLACE AIR CONDITIONING CONTROL ASSEMBLY Removal
OK -- Continue to next step.
3. CHECK HARNESS AND CONNECTOR (AIR CONDITIONING CONTROL ASSEMBLY - COMBINATION METER ASSEMBLY)
(a) Disconnect the I17 combination meter assembly connector.
(b) Measure the resistance according to the value(s) in the table below.
Standard Resistance:
NG -- REPAIR OR REPLACE HARNESS OR CONNECTOR
OK -- REPLACE COMBINATION METER ASSEMBLY Removal