Operation CHARM: Car repair manuals for everyone.
Hosted by mcallihan.com

DTC 62


DTC 62 Shift Solenoid Valve No.1 Circuit

CIRCUIT DESCRIPTION
Shifting from 1st to O/D is done in combination with ON and OFF of the shift solenoid valves No.1 and No.2 controlled by ECM. If an open or short circuit occurs in either of the solenoid valves, the ECM controls the remaining normal solenoid to allow the vehicle to be operated smoothly (Fail safe function).





Fail Safe Function
If either of the solenoid valve circuits develops a short or an open, the ECM turns the other solenoid ON and OFF to shift the gear positions shown in the table below. If both solenoids malfunction, the hydraulic control is not made electronically and can only be operated manually.
Manual shifting, as shown in the following table must be done (in the case of a short circuit, the ECM stops sending current to the short circuited solenoid).





DETECTING CONDITION
Check the shift solenoid valve No.1 when DTC 62 is output and check the shift solenoid valve No.2 when DTC 63 is output.





WIRING DIAGRAM

Step 1:




Step 2:





INSPECTION PROCEDURE