TE1, TE2 Terminal Circuit
TE1, TE2 TERMINAL CIRCUITCircuit Description
Terminals TE1 and TE2 are located in the data link connector 1.
The data link connector 1 located in the engine compartment. When these terminals are connected with the E1 terminal, diagnostic codes in normal mode or test mode can be read from the malfunction indicator lamp on the combination meter.
Diagnostic Chart
NOTE: If terminals TE1 and TE2 are connected with terminal E1, diagnostic trouble code is not output or test mode is not activated. Even though terminal TE1 is not connected with terminal E1, the malfunction indicator lamp blinks. For this phenomenon, the likely cause is an open or short in the wire harness, or malfunction inside the ECM.
Wiring Diagram
Step 1:
Step 2:
Step 3:
Inspection Procedure