Operation CHARM: Car repair manuals for everyone.
Hosted by mcallihan.com

Fault Symptom 3



No Diagnostic Trouble Codes

The fuel warning lamp does not light up or stays on the whole time. Fuel gauge normal.





Action

1 Check the fuel warning output at pin 25 of the EDU connector.

Important: Current for the lamp comes from the fuel gauge power supply, so check these supplies and their connections before assuming that the fault is in the EDU control module.

Signal Levels