Fuel Gauge Float Arm Position
With the tank unit placed on a level surface the distance between the surface and the bottom of the float should be 1.5 mm
Sensor resistance should be:
Empty tank, float in lowest position: 30 - 40 ohms.
Full tank, float in highest position: 340 - 360 ohms.
EDU code 205 should be set at +2 I.