Operation CHARM: Car repair manuals for everyone.
Hosted by mcallihan.com

61 35 ... Notes on ESD Protection (Electro Static Discharge)



61 35 ... Notes On ESD Protection (Electro Static Discharge)

Special tools required:







NOTE:
Electrical components which are particularly sensitive to electrostatic discharge (electronic control units, sensors, etc.) are marked with the ESD warning symbol.
E-Electro
S-Static
D-Discharge







IMPORTANT: Read and comply without fail with the notes on this subject from Service Information 2 06 04 128.







Statically charged persons can discharge themselves when they touch electrical components.

NOTE:
Humans can only detect a discharge starting from a level of approx. 3000 V.
The danger threshold for electrical components already starts from a level of approx. 100 V.











Example:
Mechatronic control unit.







IMPORTANT:
Do not touch pins and multi-pin connectors directly.
Touch electrical components by their housings only.

IMPORTANT:
To avoid damaging or destroying electrical components as a result of electrostatic discharge, it is absolutely essential to observe the following instructions:
- When replacing electrical components, leave the replacement components in their original packaging until immediately before they are to be installed
- If necessary, always return a removed component in its original packaging (always pack the component away immediately)
- Read and comply with user information on using the associated special tool 12 7 060







Personal protective equipment:
Electrically conducting clothing (high wool content, antistatic shoes required). These can primarily be identified by the logo on the side.