CRDC - Complaint Related Diagnostic Chart
WARNING: Risk of severe injury, ensure that no persons are within the deployment radius of the roll bar during testing and repair.
Fully extend the roll bar prior to performing any repair work. Keep body parts away from the roll bar deployment radius and its mechanism.
WARNING: Risk of severe injury, to eyes and skin from escaping high pressure hydraulic fluid spray.
Risk of poisoning due to consumption of hydraulic fluid. Depressurize the hydraulic system prior to performing repair work Wear protective clothing and safety goggles.
When performing activations via the HHT, PIN 46 of the Power Soft Top Control Module (N52) must be grounded via connection to vehicle ground. When activations are completed, remove the ground connection for PIN 46.
TIP: In order to make accurate visual inspection for oil loss from the hydraulic system, the trim panels covering the hydraulic components and rear seat assembly must be removed.
Review of Component Locations and Function Test is helpful.
Complaint/Problem