Power Trunk / Liftgate Lock Actuator: Testing and Inspection
LIFTGATE LOCK ACTUATOR INSPECTION
1. Disconnect the negative battery cable.
2. Remove the following parts:
a. Liftgate upper trim
b. Liftgate side trim
c. Liftgate recess
d. Liftgate lower trim
e. Liftgate latch and lock actuator Liftgate Latch And Lock Actuator Removal/Installation
3. Press in the latch lever using a flathead screwdriver to make the latch lever in latch condition.
4. Connect terminal D to the positive battery voltage, connect terminal B to the ground, and verify that the latch lever is released and the condition changes to the unlatch condition.
- If the operation cannot be verified, replace the liftgate latch and lock actuator.