Operation CHARM: Car repair manuals for everyone.
Hosted by mcallihan.com

Thermostatic Air Cleaner Vacuum Motor: Testing and Inspection




VARIABLE FRESH AIR DUCT (VFAD) ACTUATOR INSPECTION [13B-MSP]

With VFAD
- Remove the front bumper. Removal and Replacement
- Disconnect the vacuum hose of the VFAD actuator.
- Install the vacuum pump to the VFAD actuator.
-




Verify that the rod moves as indicated in the table below when gradually applying a vacuum to the VFAD actuator.

- If it cannot be verified, replace the fresh-air duct. Intake-Air System Removal/Installation
Rod movement