Motor Relay
1. Measure the resistance between terminals E and H, or between A and H of the ABS relay connector.
^ Resistance: 50-90 Ohms
2. Check for continuity between terminals B and F.
^ There should be not continuity between terminals B and F.
3. Apply 12 V to terminals g (+) and h (-). Check for continuity between terminals B and F.
^ There should be continuity between terminals B and F.
4. If not as specified, replace the ABS relay.