Flow Chart 7 - Lamp Flashes Ten Times
Flowchart No. 7
Note: To prevent the fail-safe system from unintentionally operating, the system-down fuse in the diagnostic module will burn if the module detects one of the following:
1. Damaged D-sensors (center, RH, and LH).
2. Open or short circuit in air bag system
Step 1
1. Disconnect the negative battery cable.
2. Disconnect the diagnostic module connector and connect the SST to it as shown in the figure.
Step 2
1. Disconnect the D-sensor connectors (center, RH, and LH).
2. Measure the resistance between terminals A and B of the D-sensor.
Step 3
- Measure the resistance between the diagnostic module connector terminals.