Pinpoint Test B: The Instrument Cluster (IC) Illumination Is Inoperative
Instrument Cluster and Panel Illumination
Pinpoint Tests
Pinpoint Test B: The Instrument Cluster (IC) Illumination Is Inoperative
Normal Operation
The Lighting Control Module (LCM) communicates the requested level of backlighting intensity to the IC through the Standard Corporate Protocol (SCP) network.
This pinpoint test is intended to diagnose the following:
- LCM
- IC
PINPOINT TEST B: THE IC ILLUMINATION IS INOPERATIVE
-------------------------------------------------
B1 CHECK THE IC NETWORK COMMUNICATION
- Ignition ON.
- Enter the following diagnostic mode on the scan tool: Network Test.
- Carry out the network test.
- Does the scan tool respond with no communication with the IC?
Yes
REFER to Information Bus.
No
INSTALL a new IC. TEST the system for normal operation.
-------------------------------------------------