Pedestrian Protection Hood Actuator LH
Pedestrian Protection Hood Actuator LH
Removal
1 Make the pedestrian protection system safe.
2 Remove the pollen filter. For additional information, refer to Pollen Filter Removal and Replacement
3 Release the power distribution box and position aside.
- Remove the 2 Torx screws.
4 Release the pedestrian protection actuator bracket.
- Release the 3 wiring harness clips.
- Remove the 4 bolts.
5 Remove the pedestrian protection actuator and bracket.
- Disconnect the electrical connector.
6 Remove the pedestrian protection actuator.
- Remove and discard the 4 Torx bolts.
Installation
1 Install the pedestrian protection actuator.
- Tighten the new Torx bolts to 8 Nm (6 lb.ft).
2 Install the pedestrian protection actuator and bracket.
- Connect the electrical connector.
3 Secure the pedestrian protection actuator bracket.
- Attach the wiring harness clips.
- Tighten the bolts to 8 Nm (6 lb.ft).
4 Position and install the power distribution box.
- Tighten the Torx bolts to 8 Nm (6 lb.ft).
5 Install the pollen filter. For additional information, refer to Pollen Filter Removal and Replacement