C9: Check Harness Continuity - Signal (Mechanical Guard)
With conditions as C8, measure the resistance between PI0042/001 and EM011/013
- Is the resistance < 0.5 (ohms)?
Yes
GO to C10 C10: Harness Short to Screen
No
Inspect PI042, EM011, and PI001 for bent/pushed back pins or locate harness. Repair as necessary and test the system for normal operation.