A6: Check Fuel Pump Drawn Current
NOTE: With EM013 disconnected this test will cause the pump to operate continuously. Do not exceed 10 sec running.
NOTE: Do not replace relay.
With the ignition energized, measure the current drawn between relay socket pins 3 and 5.
- Is the current between 2.5 and 9 A?
Yes
GO to A7 A7: Check B+ At Relay Coil
No
GO to A10 A10: Check Fuel Pump Continuity