C6: Check For Short to Ground
With EM013 and CV001 disconnected, measure the insulation resistance between EM013/004 and ground EM010/022.
- Is the resistance > 10 M ohms?
Yes
Reconnect EM010
GO to C7 C7: End
No
Inspect harness/connectors EM013, EM002, FC001 and CV001 for damage, corrosion, bent/pushed back pins. Repair as necessary and test the system for normal operation.