E7: Heated O2 Sensor Short Circuit to Ground
With EM023 disconnected measure the insulation resistance between sensor pin 001 and sensor body. Repeat for pin 003 and sensor body.
- Is the resistance > 10 M ohms?
Yes
GO to E9 E9: Signal Ground/Continuity
No
Renew the O2 sensor and reconnect plug(s)
GO to E8 E8: Stop