Power Supply and Ground Circuit Inspection
COMBINATION METERS
Power Supply and Ground Circuit Inspection
Symptom : When any power supply circuit is malfunction, the following function is not operative.
- BAT : Meter face illumination, Dot matrix LCD, Ring illumination, Turn signal/hazard indicator lights
- ACC : Meter face illumination, Dot matrix LCD, Pointer illumination, Speedometer, Tachometer
- IGN : Meter face illumination, Dot matrix LCD, Pointer illumination, Speedometer, Tachometer, Engine coolant temperature, Fuel gauge
1.CHECK FUSE
Check for blown fuses.
OK or NG
OK - GO TO 2.
NG - Be sure to eliminate cause of malfunction before installing new fuse. Refer to Schematic.
2.CHECK POWER SUPPLY CIRCUIT
Check voltage between combination meter harness connector and ground.
OK or NG
OK - GO TO 3.
NG - Check harness between combination meter and fuse.
3.CHECK GROUND CIRCUIT
1. Turn ignition switch OFF.
2. Disconnect combination meter connector.
3. Check continuity between combination meter harness connector and ground.
OK or NG
OK - INSPECTION END
NG - Repair harness or connector.