Warning Lamp and Indicator Lamp Circuit
Warning Lamp and Indicator Lamp CircuitINSPECTION PROCEDURE
1. CHECK SELF-DIAGNOSIS RESULTS
Perform ABS actuator and electric unit (control unit) self-diagnosis.
OK or NG
OK >> GO TO 2.
NG >> Check items displayed by self-diagnosis. Refer to BRC-24, "Self-Diagnosis". Self-Diagnosis
2. CHECK COMBINATION METER
Check the indication and operation of combination meter are normal. Refer to DI-17, "Self-Diagnosis Mode of Combination Meter".
OK or NG
OK >> INSPECTION END
NG >> Combination meter is malfunctioning. Repair or replace combination meter.