Diagnostic Procedure 3
DIAGNOSTIC PROCEDURE 3Final inspection after repairing SRS by using CONSULT-II - Diagnosis mode
Refer to GI-37, "CONSULT-II Start Procedure". With Manufacturer's Scan Tool
CAUTION: If CONSULT-II is used with no connection of CONSULT-II CONVERTER, malfunctions might be detected in self-diagnosis depending on control unit which carry out CAN communication.
1. Touch "SELF-DIAG [CURRENT]".
2. If no malfunction is detected on "SELF-DIAG [CURRENT]", repair of SRS is completed. Go to step 3.
If any malfunction is detected on "SELF-DIAG [CURRENT]", the malfunctioning part is not repaired completely or another malfunctioning part is detected. Go to SRS-22, "DIAGNOSTIC PROCEDURE 2" , and repair malfunctioning part completely. Diagnostic Procedure 2
3. Touch "ERASE".
NOTE: Touch "ERASE" to clear the memory of the malfunction ("SELFDIAG [PAST]").
If the memory of the malfunction in "SELF-DIAG [PAST]" is not erased, the User mode shows the system malfunction by the operation of the warning lamp even if the malfunction is repaired completely.
4. Touch "BACK" key of CONSULT-II to "SELECT DIAG MODE" screen. Touch "SELF-DIAG [PAST]".
5. Make sure no malfunction is detected on "SELF-DIAG [PAST]".
6. Touch "BACK" key of CONSULT-II until "SELECT SYSTEM" appears in order to return to User mode from Diagnosis mode.
7. Turn ignition switch OFF then turn off and disconnect CONSULT-II. Go to SRS-20, "Checking Air Bag Operation by Using "AIR BAG" Warning Lamp - User Mode" SRS Operation Check