Operation CHARM: Car repair manuals for everyone.
Hosted by mcallihan.com

C1116

Stop Lamp Switch System

INSPECTION PROCEDURE
1. CHECK SELF-DIAGNOSTIC RESULTS
Check the self-diagnostic results.





Is above displayed in the self-diagnosis item?
YES >> GO TO 2.
NO >> INSPECTION END

2. CHECK CONNECTOR
1. Turn ignition switch OFF and disconnect stop lamp switch connector and VDC/TCS/ABS control unit connector.
2. Reconnect connectors securely.
3. Start engine.
4. Repeat pumping brake pedal carefully several times, then perform self-diagnosis.
Do any self-diagnostic items appear?
YES >> GO TO 3.
NO >> Poor connection. Repair or replace connector.

3. CHECK STOP LAMP SWITCH








1. Turn ignition switch OFF and disconnect stop lamp switch harness connector.
2. Operate stop lamp switch and check continuity between stop lamp switch harness connector terminals.
OK or NG
OK >> GO TO 4.
NG >> Replace stop lamp switch.

4. CHECK STOP LAMP SWITCH CIRCUIT








1. Turn ignition switch OFF and disconnect VDC/TCS/ABS control unit harness connector.
2. Check continuity between VDC/TCS/ABS control unit harness connector M93 terminal 48 and ground.
OK or NG
OK >> Perform VDC/TCS/ABS control unit self-diagnosis again.
NG >> Open or short in harness between VDC/TCS/ABS control unit and stop lamp switch