Operation CHARM: Car repair manuals for everyone.
Hosted by mcallihan.com

Auxiliary Mechanism: Temperature Setting Trimmer

The trimmer compensates for differences in range of ± 3°C (± 6°F) between temperature setting (displayed digitally) and temperature felt by driver.




Operating procedures for this trimmer are as follows:
- Begin Self-diagnosis STEP 5 mode. Step-By-Step Procedure
- Press (fan) UP switch to set system in auxiliary mode.
- Display shows "61" in auxiliary mechanism. It takes approximately 3 seconds.
- Press either (HOT) or (COLD) switch as desired. Temperature will change at a rate of 0.5 °C (1.0 °F) each time a switch is pressed.

When battery cable is disconnected, trimmer operation is canceled. Temperature set becomes that of initial condition, i.e. 0 °C (0 °F).