Air Cleaner Fresh Air Duct/Hose: Service and Repair
Air Cleaner Resonator Outlet Duct Replacement
Removal Procedure
1. Remove the intake manifold sight shield. Refer to.
2. Loosen the clamp and separate the air cleaner resonator outlet duct from the mass air flow/intake air temperature (MAF/IAT) sensor assembly.
3. Loosen the clamp and separate the air cleaner resonator outlet duct from the throttle body assembly.
4. Disconnect the positive crankcase ventilation (PCV) tube from the outlet duct.
5. Remove the air cleaner resonator outlet duct.
Installation Procedure
1. Install the air cleaner resonator outlet duct to the throttle body assembly and the MAF/IAT sensor assembly.
2. Connect the PCV tube to the outlet duct.
3. Tighten the clamps at the throttle body assembly and the MAF/IAT sensor assembly.
Caution: Refer to Fastener Caution (Fastener Caution).
Tighten the clamps to 5 Nm(44 lb in)
4. Install the intake manifold sight shield. Refer to.