DTC 15
DTC 15: A Short in the Evaporator Temperature Sensor Circuit1. Remove the evaporator temperature sensor.
2. Test the evaporator temperature sensor.
Is the resistance within the specifications shown on the graph?
YES - Go to step 3.
NO - Replace the evaporator temperature sensor.
3. Disconnect climate control unit connector B (22P).
4. Check for continuity between the No.7 terminal of climate control unit connector B (22P) and body ground.
Is there continuity?
YES - Repair short to body ground in the wire between the climate control unit and the evaporator temperature sensor.
NO - Substitute a known-good climate control unit, and recheck. If the symptom/indication goes away, replace the original climate control unit.