Test L: One Turn Signal/Hazard Lamp Is Inoperative/Always On
PINPOINT TEST L: ONE TURN SIGNAL/HAZARD LAMP IS INOPERATIVE/ALWAYS ONNormal Operation
When the smart junction box (SJB) detects the multifunction switch in the LH TURN position, the SJB provides on/off voltage through circuit CLS21 (BU/GN) to the LH front turn lamp. Circuit GD120 (BK/GN) provides ground to the LH front turn lamp.
When the SJB detects the multifunction switch in the RH TURN position, the SJB provides on/off voltage through circuit CLS25 (YE/VT) to the RH front turn lamp. Circuit GD164 (BK/VT) provides ground to the RH front turn lamp.
The rear lamps are combination stop/turn lamps that are controlled through the rear stoplamp circuitry.
B2A27-B2A2A:
This pinpoint test is intended to diagnose the following:
- Wiring, terminals or connectors
- Bulb holder
- SJB