Operation CHARM: Car repair manuals for everyone.
Hosted by mcallihan.com

Test A: The Roof Opening Panel Does Not Open Or Close

PINPOINT TEST A: THE ROOF OPENING PANEL DOES NOT OPEN OR CLOSE

Normal Operation
The roof opening panel motor is supplied voltage through circuit SBP47 (WH/RD) when the ignition key is in the ACC or RUN position. The roof opening panel motor is grounded through circuit GD133 (BK). The roof opening panel switch is grounded through circuit GD133 (BK). When the roof opening panel switch is pressed, it supplies a ground on circuit CPR31 (VT/BN) for DOWN/OPEN or to circuit CPR40 (YE/OG) for UP/CLOSE.

This pinpoint test is intended to diagnose the following:
- Circuit breaker
- Wiring, terminals or connectors
- Roof opening panel switch
- Roof opening panel motor


A1-A3:






A4-A6: