Tests AL: DTC B2228 - Air Bag Driver Circuit Short to Ground Loop #2 Fault
PINPOINT TEST AL: DTC B2228 - AIR BAG DRIVER CIRCUIT SHORT TO GROUND LOOP #2 FAULTAL1-AL3:
AL3-AL4:
AL5-AL7:
Normal Operation
The restraints control module (RCM) checks all of the driver air bag circuits for faults. If the RCM detects a short to ground on any of the driver air bag module squib 2 circuits, it will store diagnostic trouble code (DTC) B2228 in memory and illuminate the air bag indicator.
Fault Conditions
The RCM monitors for the following fault condition:
- Circuit short to ground
Possible Causes
A driver air bag module squib 2 circuit short to ground fault can be caused by:
- damaged wiring, terminals or connectors.
- a faulty clockspring.
- a faulty driver air bag module.
- a faulted RCM.