Operation CHARM: Car repair manuals for everyone.
Hosted by mcallihan.com

Test G: The Battery Saver Does Not Deactivate After Timeout

PINPOINT TEST G: THE BATTERY SAVER DOES NOT DEACTIVATE AFTER TIMEOUT


G1-G2:






G2-G4:






Normal Operation
The generic electronic module (GEM) provides a ground circuit for the battery saver relay through circuit 31S-LC22 (BK/OG). The battery saver relay provides power to circuit 29-LC7 (OG/BU). Circuit 29-LC7 (OG/BU) provides power to each demand lamp switch. When the demand lamp switch is activated, power is provided to the selected demand lamp.

Possible Causes
- Circuit 29-LC7 (OG/BU) short to voltage
- Circuit 31S-LC22 (BK/OG) short to ground
- Battery saver relay
- GEM