Operation CHARM: Car repair manuals for everyone.
Hosted by mcallihan.com

Test A: The Roof Opening Panel Does Not Open or Close

PINPOINT TEST A: THE ROOF OPENING PANEL DOES NOT OPEN OR CLOSE


A1-A3:






A4-A6:






A6-A8:






Normal Operation
The roof opening panel motor is supplied voltage through circuit 15-AG12 (GN/BK) and 29-AG12 (OG/BK) when the ignition key is in the ACC or RUN position. The roof opening panel motor is grounded through circuit 31-AG12 (BK). The roof opening panel switch is supplied voltage through circuit 15-AG7 (GN/BU) when the ignition key is in the ACC or RUN position. The roof opening panel switch is grounded through circuit 31-AG7 (BK). When the roof opening panel switch is pressed it connects circuit 31-AG12 (BK) to circuit 31S-AG27 (BK/WH) for DOWN/OPEN or to circuit 31S-AG7 (BK/BU) for UP/CLOSE.

Possible Causes
- fuse(s)
- circuit 15-AG7 (GN/BU) open
- circuit 29-AG12 (OG/BK) open
- circuit 31-AG7 (BK) open
- circuit 31-AG12 (BK) open
- circuit 31S-AG7 (BK/BU) open
- circuit 31S-AG27 (BK/WH) open
- roof opening panel switch
- roof opening panel motor