Test C: One Or More Smart Junction Box (SJB) Controlled Illumination Source(s) Is Inoperative
PINPOINT TEST C: ONE OR MORE SMART JUNCTION BOX (SJB) CONTROLLED ILLUMINATION SOURCE(S) IS INOPERATIVEC1-C4:
C4-C7:
C7-C8:
C8-C9:
C10-C12:
Normal Operation
Dimmable Backlighting
When the headlamp lamp switch is placed in the PARK or headlamps ON position, a voltage signal is supplied to the instrument panel dimmer switch through circuit 1036 (BN/WH) from the smart junction box (SJB). The dimmer switch passes this voltage through a variable resister and then returns the signal to the SJB on circuit 1035 (OG/RD). The SJB uses the return signal to determine the backlighting intensity desired by the operator. A pulse width modulated (PWM) signal is sent from the SJB to each of the dimmable backlights maintaining the operator's desired level of lighting intensity.
Non-Dimable Backlighting
When the ignition switch is placed in the ACCY or the ON position, a voltage signal is supplied to the SJB. The SJB activates the accessory delay relay, supplying voltage to the non-dimmable backlights.
Possible Causes
- circuit 19 (LB/RD) open or short to ground
- circuit 1403 (BK/WH) open or short to ground
- circuit 2030 (YE/WH) open or short to ground
- circuit 293 (OG/RD) open or short to ground
- circuit 203 (OG/LB) open or short to ground
- circuit 2023 (YE/LB) open or short to ground
- circuit 2029 (LB/WH) open or short to ground
- circuit 985 (RD/LB) open or short to ground
- circuit 333 (YE/RD) open or short to ground
- circuit 984 (YE/LB) open or short to ground
- circuit 1425 (GY/WH) open or short to ground
- circuit 1205 (BK) open
- circuit 1405 (LB/BK) open
- illuminated component
- clockspring
- SJB
- accessory delay relay
- speed control switch