FDS15 - Check Pump Speeds
^ Key Off.
^ Connect DVOM into Inertia Fuel Shutoff (IFS) switch connector.
^ Start engine and monitor voltage at the IFS.
^ Is voltage between 12.0 and 14.0 volts during crank and initial idle speed, then drops between 7.0 and 10.0 volts after a short time?
YES -- Go to FDS17. FDS16 - Check Pressure Difference
NO -- Dual voltage system may be damaged. Perform Quick Test and repair DTC codes.