1, 2 and 3 Digit Codes: 96
Trouble Code Number
- Scan tool 96
- General scan tool P1698
- MIL 66
Fault Message
No CCD Messages From TCM
- The TCM outputs no CCD messages.
Probable Cause
- Communication line between PCM and TCM failed
- TCM failed
- PCM failed