Operation CHARM: Car repair manuals for everyone.
Hosted by mcallihan.com

Instrument Panel Cluster (IPC) - Replacement



Instrument Cluster Replacement

Removal Procedure

1. Remove the IP cluster trim plate. Refer to Instrument Cluster Trim Panel Replacement (Instrument Cluster Trim Panel Replacement) .




2. Remove the screws from the IP cluster to instrument panel.
3. Remove the IP cluster from the instrument panel.




4. Disconnect the electrical connectors.



Installation Procedure





1. Connect the electrical connectors.




2. Position the IP cluster to the instrument panel.

Notice: Refer to Fastener Notice in Cautions and Notices.

3. Install the screws that retain the IP cluster to the instrument panel.

Tighten the screws to 2.5 N.m (22 lb in).
Ensure that the screws are tightened in the following sequence:

1. Lower left screw
2. Lower right screw
3. Upper left screw
4. Upper right screw

4. Install the instrument cluster trim plate. Refer to Instrument Cluster Trim Panel Replacement (Instrument Cluster Trim Panel Replacement) .



Instrument Panel Cluster Synchronization

Tools Required

Scan Tool

When installing a new IP cluster it must be synchronized to the supplemental inflatable restraint (SIR) module in order to synchronize the new cluster, perform the following steps:

1. Connect the to the data link connector (DLC).
2. Proceed to the SPECIAL FUNCTIONS key under INSTRUMENT PANEL CLUSTER.
3. Select the SYNCHRONIZE IPC and SIR key.
4. The screen will display: IPC and SIR modules-Now synchronizing modules.
5. If the procedure is completed successfully the screen will display: Module Synchronization Complete.
6. If communication is lost with the SIR or IPC, the screen will display: Loss of Communications with Vehicle - Check Diagnostics Link Connector - Check Ignition (On/Off).