Operation CHARM: Car repair manuals for everyone.
Hosted by mcallihan.com

Chart C-12 Coolant Fan Control Circuit

Chart C12: Part 1 0f 2:




Chart C12: Part 2 0f 2:




Cooling Fan Circuit:






CIRCUIT DESCRIPTION
The cooling fans are controlled by the Powertrain Control Module (PCM) based on various inputs. Battery voltage is supplied to the primary and secondary fan relays on terminal "30." Ignition voltage is supplied to terminal "85" of the primary and secondary fan relays. Grounding CKT 335 (relay terminal "86") will energize the primary cooling fan relay (Fan 1) and supply battery voltage to the primary cooling fan motor. Grounding CKT 473 (relay terminal "86") will energize the secondary cooling fan relay (Fan 2) and supply battery voltage to the secondary fan motor.

When certain Diagnostic Trouble Codes (DTCs) are set, the PCM will enable the cooling fans.

DTC CHART TEST DESCRIPTION
Numbers below refer to circled numbers on the diagnostic chart.

1. With the output/field service enable terminal grounded at DLC, the cooling fan control driver(s) will close, which should energize the fan control relay(s).
2. Engine coolant temperature must be below 100°C (212°F) to perform this step.
3. The cooling fans should come "ON" anytime A/C system is operating.
4. Comparing Tech 1 pressure and manifold gage set pressure will determine if the A/C refrigerant pressure sensor is out of range. An out of range A/C refrigerant pressure sensor can cause the cooling fans to operate at the wrong times.

DIAGNOSTIC AIDS
If the owner complained of an overheating problem, it must be determined if the complaint was due to an actual boil over, or the warning indicator light, or engine coolant temperature gage indicated overheating.

The gage accuracy can also he checked by comparing the Engine Coolant Temperature (ECT) sensor reading using a Tech 1 scanner and comparing its reading with the gage reading.

If the engine is actually overheating and the gage indicated overheating, but the cooling fan is not coming "ON," the ECT sensor has probably shifted out of calibration and should be replaced.

If the engine is overheating and the cooling fans are "ON," the cooling system should be checked.

The PCM will command fan 1 "ON" at 107°C (225°F) and "OFF" at 103°C (217°F) and, fan 2 "ON" at 111°C (232°F) and "OFF" at 107°C (224°F).