1215 - Air Flow Meter
Air Flow Meter/Idle Valve/Throttle Switch Location:
1. Disconnect the air flow meter harness connector.
Injection Electronics. Wiring Diagram:
2. With the ignition switch in the run position (ON), measure the following voltages at the harness connector.
^ Gray/white wire (terminal 3) and ground = Approx. 5 volts
^ Gray/white and gray/yellow wire (terminals 3 and 2) = Approx. 5 volts
^ Gray/white and gray/blue wire (terminals 3 and 4) = Approx. 5 volts
3. If any voltage is incorrect, check and repair associated connections and wires for opens and shorts to voltage and ground.
^ If wires and connections are OK, replace the DME control unit.
4. If all voltages are correct check for continuity between the following terminals at the air flow meter connector (male plug). Measure between pins:
^ 7 and 26 = Continuity
^ 7 and 12 = Continuity
^ If any results are incorrect, replace the air flow meter.
^ If all results are correct, proceed to step 5.
5. Reconnect the air flow meter harness connector and remove the rubber insulation cover.
6. Measure the voltage between gray/yellow wire (terminal 2), and ground while moving the intake air flap manually.
^ If voltage varies between approximately 0.5 and 4.5 volts, check or repair wire to terminal 7 of DME control unit harness connector for an open circuit. If wire is OK, replace the DME control unit.
^ If the voltage does not vary between 0.5 and 4.5 volts, check or repair wire to terminal 7 of DME control unit harness connector for short to ground. If wiring is OK, repair or replace the air flow meter.