Air Injection Pump: Service and Repair
Secondary Air Injection Pump Motor
Removing
- Remove noise insulation.
- Remove the secondary air hoses - 1 - and - 2 - from the Secondary Air Injection (AIR) Pump Motor (V101) by pressing the release buttons.
- Disconnect electrical connector - 3 -.
- Remove the nuts and remove the secondary air pump.
Installing
• Tightening specifications, refer to => [ Secondary Air Injection System Assembly Overview ] Service and Repair.
Installation is in reverse order of removal, note the following:
• During installation, all cable ties must be re-installed at the same location.
- Install the noise insulation.