Connecting Rod, Measuring Radial Clearance
Connecting Rod, Measuring Radial Clearance
Special tools, testers and auxiliary items required
• Plastigage
Test Sequence
- Remove connecting rod bearing caps.
- Clean bearing caps and journals
- Place Plastigage over entire width of bearing journal or into bearing shells.
- Install connecting rod bearing cap and tighten to 30 Nm. Do not turn crankshaft.
- Remove connecting rod bearing caps again.
- Compare width of Plastigage with measuring scale:
• Radial clearance new: 0.028 to 0.077 mm.
• Radial clearance wear limit: 0.12 mm.
- Replace bolts for connecting rod bearings.