Left Front Exhaust Pipe With Catalytic Converter, Automatic Transmission
Left Front Exhaust Pipe with Catalytic Converter, Automatic Transmission
Special tools, testers and auxiliary items required
• Engine/transmission jack (V.A.G 1383 A)
Removing
• All cable ties which are opened or cut open when removing, must be replaced in the same position when installing.
- Remove rear engine cover - arrows -.
- Remove coolant expansion tank - arrow -.
- Disconnect electrical connection from Engine Coolant Level (ECL) Warning Switch (F66) at bottom of coolant reservoir and set aside coolant reservoir with coolant hoses - 1 - and - 2 - connected.
- Disconnect electrical harness connector - 1 - for Oxygen Sensor (O2S) 2 Behind Three Way Catalytic Converter (TWC) (G131) and free up wiring.
• Ignore - 2 -.
- Remove nut - 2 - which is accessible from top for front exhaust pipe/exhaust manifold.
• To improve clarity, the removed engine is shown from the rear.
- Remove left front wheel.
- Loosen quick-release fasteners - 1 through 3 - and remove front and rear noise insulation.
- Remove heat shield - arrows - for left drive axle.
- Remove left driveshaft from transmission flange shaft.
- Remove nuts - 1 - and - 3 - which are accessible from bottom for front exhaust pipe/exhaust manifold.
• To improve clarity, the removed engine is shown.
- Remove bolts - 1 - and - 2 -.
- Remove bracket for front exhaust pipe.
- Disconnect exhaust system at double clamps - arrows -.
- Remove bolts - arrows - for left and right transmission mount.
- Place lifting surface of Engine/Transmission Jack (V.A.G 1383 A) centrally on lower housing base - arrow - and lift transmission slightly.
- Remove heat shield for left transmission support.
- Unfasten left transmission support with transmission mount - arrows -.
- Carefully push transmission upward with Engine/Transmission Jack (V.A.G 1383 A), until transmission tunnel touches the body.
- Guide front exhaust pipe downward and out between transmission and subframe using twisting movements.
Installing
Installation is in reverse order of removal, noting the following:
• Replace gaskets and self-locking nuts.
• During installation, all cable ties must be re-installed at the same location.
• Electrical wire of oxygen sensor must always be secured in the same position when installing so that contact with the exhaust pipe is avoided.
- Install transmission support and transmission mount.
- Install drive axle.
- Align exhaust system. Refer to => [ Exhaust System, Installing ] Exhaust System, Installing.
• Individual components of exhaust system mounting => [ Individual left mounting components - vehicles
with automatic transmission 09L ] Exhaust System Component Overview
Tightening Specifications